CalBench Process Calibration Modules
7085 Temperature Distribution Panel
-
- For multiple testing of thermocoples with 7051 or 5065B and dry block calibrator (7070/7071/7072)
- Switches 7 thermocouple inputs & 1 RTD reference to a common output
- Records min/max ambient temperatures
- Cold junction temperature display
- Clear visual display of temperature (LCD)
- Automatic switching version - 7085A
View Data Sheet
7001 PT100 Simulator
- -200°C to +800°C with 23 set points
- ± 0.3°C accuracy
- Exceeds class A
- Excellent temperature stability
- Passive resistance source
- °F version available upon request
View Data Sheet
7068 RTD Temperature Calibrator
- Temperature accuracy 0.05°C (0.09°F)
- Temperature resolution 0.01°C (0.02°F)
- Resistance accuracy 0.03Ω, resolution 0.01Ω
- 2, 3, and 4 wire connections
- Measure and simulate °C, °F, °K, & Ω
- User programmable with ramp and step modes
- PT100 plus 7 other RTD types
View Data Sheet
7077 Process Calibrator
- Measure and simulate 8 thermocouples
- Measure and simulate PT100-RTD
- Measure and source μV, mV, mA
- Displays units in °C, °F, μV/mV, or mA
- Automatic or manual cold junction compensation
- Process loops 4 to 20mA & 0 to 50mA
- 24V loop drive voltage
View Data Sheet
7061 Multifunction Process Calibrator
- Measure (3 ranges) up to 40V, 400mA, 40kΩ
- Output voltage (3 ranges) to 10V, 1μV resolution
- Output current (3 ranges) to 20mA, 1μA resolution
- Output resistance: 0 to 400Ω, 0.01Ω resolution
- Thermocouple measure/simulate: J, K, T, E, R, S, B, N
- RTD measure and simulate: PT100
- Ramp function
View Data Sheet
7067 Loop Calibrator
- Current measure: 125mA, source: 50mA
- Voltage measure: 25V, source: 21V
- Loop Current Sink
- Accuracy 0.01%, resolution 1μA or 1mV
- Transmitter and square root functions
- Auto-ranging feature
- Programmable steps and ramp
View Data Sheet
7069 V/I Loop Calibrator
- Source and measure voltage and current
- 3 source ranges: 0 to 22mA and 0 to 22V
- 3 measure ranges: 0 to 70mA and 0 to 50V
- Accuracy 0.02%
- Transmitter simulator/sink loop control
- Output steps and ramps
- Fine adjustment (inching)
View Data Sheet
7079 Loop Ancilliaries Module
- Loop measure 0 to 200mA
- 4.5 digit display
- Continuity test
- 24V output for powering 4 - 20mA loops
- Overload protection to loop
- Supply line protection by F250mA fuse
- EasyCal software communication via RS-232
View Data Sheet
7002 / 7003 / 7004: HART & Foundation Fieldbus Communication Modules
- 7002 HART Communication Module
- 7003 Foundation Fieldbus Communication Module
- 7004 Combined HART & FF Comms Module
- EasyCal software applications for HART & FF
- Device configuration & readback
- Conditioned power and network termination
View Data Sheet