About CalBench >> Modules >> Process Calibration Modules

CalBench Process Calibration Modules

7085 Temperature Distribution Panel

    • For multiple testing of thermocoples with 7051 or 5065B and dry block calibrator (7070/7071/7072)
    • Switches 7 thermocouple inputs & 1 RTD reference to a common output
    • Records min/max ambient temperatures
    • Cold junction temperature display
    • Clear visual display of temperature (LCD)
    • Automatic switching version - 7085A
    View Data Sheet

7001 PT100 Simulator

  • -200°C to +800°C with 23 set points
  • ± 0.3°C accuracy
  • Exceeds class A
  • Excellent temperature stability
  • Passive resistance source
  • °F version available upon request
View Data Sheet

7068 RTD Temperature Calibrator

  • Temperature accuracy 0.05°C (0.09°F)
  • Temperature resolution 0.01°C (0.02°F)
  • Resistance accuracy 0.03Ω, resolution 0.01Ω
  • 2, 3, and 4 wire connections
  • Measure and simulate °C, °F, °K, & Ω
  • User programmable with ramp and step modes
  • PT100 plus 7 other RTD types
View Data Sheet

7077 Process Calibrator

  • Measure and simulate 8 thermocouples
  • Measure and simulate PT100-RTD
  • Measure and source μV, mV, mA
  • Displays units in °C, °F, μV/mV, or mA
  • Automatic or manual cold junction compensation
  • Process loops 4 to 20mA & 0 to 50mA
  • 24V loop drive voltage
View Data Sheet

7061 Multifunction Process Calibrator

  • Measure (3 ranges) up to 40V, 400mA, 40kΩ
  • Output voltage (3 ranges) to 10V, 1μV resolution
  • Output current (3 ranges) to 20mA, 1μA resolution
  • Output resistance: 0 to 400Ω, 0.01Ω resolution
  • Thermocouple measure/simulate: J, K, T, E, R, S, B, N
  • RTD measure and simulate: PT100
  • Ramp function
View Data Sheet

7067 Loop Calibrator

  • Current measure: 125mA, source: 50mA
  • Voltage measure: 25V, source: 21V
  • Loop Current Sink
  • Accuracy 0.01%, resolution 1μA or 1mV
  • Transmitter and square root functions
  • Auto-ranging feature
  • Programmable steps and ramp
View Data Sheet

7069 V/I Loop Calibrator

  • Source and measure voltage and current
  • 3 source ranges: 0 to 22mA and 0 to 22V
  • 3 measure ranges: 0 to 70mA and 0 to 50V
  • Accuracy 0.02%
  • Transmitter simulator/sink loop control
  • Output steps and ramps
  • Fine adjustment (inching)
View Data Sheet

7079 Loop Ancilliaries Module

  • Loop measure 0 to 200mA
  • 4.5 digit display
  • Continuity test
  • 24V output for powering 4 - 20mA loops
  • Overload protection to loop
  • Supply line protection by F250mA fuse
  • EasyCal software communication via RS-232
View Data Sheet

7002 / 7003 / 7004: HART & Foundation Fieldbus Communication Modules

  • 7002 HART Communication Module
  • 7003 Foundation Fieldbus Communication Module
  • 7004 Combined HART & FF Comms Module
  • EasyCal software applications for HART & FF
  • Device configuration & readback
  • Conditioned power and network termination
View Data Sheet